JA
Tripp Lite logo
公式取扱説明書

Tripp Lite SMX1500RXLRT2U+

2 ページ·425 KB·電源ユニット·PDF·EN
Tripp Lite SMX1500RXLRT2U+
目次 1セクション T ripp L ite UPS S ystems S olution G uide 表示非表示
Page 1 of the Tripp Lite SMX1500RXLRT2U+ user manual — T ripp L ite UPS S ystems S olution G uide
1ページ · クリックして拡大
1ページ

T ripp L ite UPS S ystems S olution G uide

and Runtime Chart for Cisco Ideal for Protecting and Powering Mission-Critical Cisco Equipment

Questions? Contact: David Inwood New Business Development Manager Tel +44 (0)1622 852827 [email protected] Gary Crook - Account Manager Tel: +44 (0)1622 852816 [email protected] Samuel Hartridge - Account Manager Tel: +44 (0)1622 852813 [email protected] UPS Systems SmartPro® UPSSmartOnlineTM UPS SMX500RT1USMX1000RT2USMX1500XLRT2USMX1500RXLRT2U + BP36V15-2USMX2200XLRT2USMX2200XLRT2U + BP48V60RT3USUINT10002TXL2UaSUINT1000RTXL2Ua+ BP24V28-2USUINT1500RTXL2UaSUINT1500RTXL2Ua+ BP48V24-2USUINT2200RTXL2UaSUINT2200RTXL2Ua+ BP48V60RT3U Cisco DevicePower RequirementEstimated Runtime in Minutes* Cisco 184150w3114019780732818941365161918382201344 Cisco 2801150w84672289113756452187235091626 Cisco 2801 with IP Phone Power270w3233715358423221213719549367 Cisco 2811170w7406325498671391946331180591 Cisco 2811 with IP Phone Power370w—15261074030515862613935269 Cisco 2821280w3223614655407211163618747354 Cisco 2821 with IP Phone Power550w—8166624197953168922178 Cisco 2851280w3223614655407211163618747354 Cisco 2851 with IP Phone Power730w——11451814363711631563 Cisco 3825330w—18301224634417983015738302 Cisco 3825 with IP Phone Power650w—7135320163743137318148 Cisco 3845440w—1221873225312702111528225 Cisco 3845 with IP Phone Power720w——114618145638116415132 Cisco ASA 550596w1364117412164103860297102477125821 Cisco ASA 5510190w6355622687603341745627972511 Cisco ASA 5520190w6355622687603341745627972511 Cisco ASA 5540190w6355622687603341745627972511 Cisco ASA 5550190w6355622687603341745627972511 Cisco ASA 5580800w——94017129433105614117 Cisco Catalyst 2960-24LT-L175w6366424093637351845929576537 Cisco Catalyst 2960-24PC-L470w—1119803023511651910626210 Cisco Catalyst 2960-24TC-L30w542113811205492267215368626911332941722 Cisco Catalyst 2960-24TT-L30w542113811205492267215368626911332941722 Cisco Catalyst 2960-48TC-L45w3414426787235520281195472058922341416 Cisco Catalyst 2960-48TT-L45w3414426787235520281195472058922341416 Cisco Catalyst 2960-8TC-L20w712474751474601318418079331913213401955 Cisco Catalyst 2960G-24TC-L75w19911665662281383813891386281651049 Cisco Catalyst 2960G-48TC-L140w94785309121802452317637197660 Cisco Catalyst 2960G-8TC-L30w542113811205492267215368626911332941722 Cisco Catalyst 2960PD-8TT-L11w1073905072211902477638111904777261871075

* Runtimes may vary due to load and battery condition. Tripp Lite follows a policy of continuous improvement. Specifications are subject to change without notice.

Page 2 of the Tripp Lite SMX1500RXLRT2U+ user manual — T ripp L ite UPS S ystems S olution G uide
2ページ · クリックして拡大
2ページ
Questions? Contact: David Inwood New Business Development Manager Tel +44 (0)1622 852827 [email protected] Gary Crook - Account Manager Tel: +44 (0)1622 852816 [email protected] Samuel Hartridge - Account Manager Tel: +44 (0)1622 852813 [email protected] UPS Systems SmartPro® UPSSmartOnlineTM UPS SMX500RT1USMX1000RT2USMX1500XLRT2USMX1500RXLRT2U + BP36V15-2USMX2200XLRT2USMX2200XLRT2U + BP48V60RT3USUINT10002TXL2UaSUINT1000RTXL2Ua+ BP24V28-2USUINT1500RTXL2UaSUINT1500RTXL2Ua+ BP48V24-2USUINT2200RTXL2UaSUINT2200RTXL2Ua+ BP48V60RT3U Cisco DevicePower RequirementEstimated Runtime in Minutes* Cisco Catalyst 3560-24TS-S/E45w3414426787235520281195472058922341416 Cisco Catalyst 3560-48TS-S/E65w221041906412591546914311556971831149 Cisco Catalyst 3560-8PC-S204w5295219775531291534824663454 Cisco Catalyst 3560E-12D300w3203313551379191083317444331 Cisco Catalyst 3560E-12SD300w3203313551379191083317444331 Cisco Catalyst 3560E-24PD750w——104418139536116115126 Cisco Catalyst 3560E-24TD265w4223915659431231233819850374 Cisco Catalyst 3560E-48PD750w——104418139536116115126 Cisco Catalyst 3560E-48PD-SF1150w————981——636875 Cisco Catalyst 3560E-48TD265w4223915659431231233819850374 Cisco Catalyst Express 520-24LC110w12659939515710016328798461121801 Cisco Catalyst Express 520-24PC460w—1120823024111662010927215 Cisco Catalyst Express 520-24TT30w541833811205192267215368726911332931722 Cisco Catalyst Express 520G-24TC45w3414526787235520281195472058922341416 Cisco Secure ACS Engine345w—17291164332817932815037289 Cisco UC520 – 8-user190w6355622687603341745627972511 Cisco UC520 – 16-user190w6355622687603341745627972511 Cisco UC520 – 24-user200w5335321382572321655326568487 Cisco UC520 – 32-user200w5335321382572321655326568487 Cisco UC520 – 48-user200w5335321382572321655326568487 MCS-7815-I2400W—1423973628012792312732249 MCS-7825-H2450W—1220853124711682011227220 MCS-7825-I2350W—17281144232316922814837285 MCS-7835-12835W REDUNDANT P/S——93815122——95313111 MCS-7835-H21000W REDUNDANT P/S——7291197——7421092 WS-C3550G-24PS/WS-3750G-24PS540W—9166725201954169122181 WS-C3560-24PS/WS-C3750-24PS485W/495W—1018772822510611810225201 WS-C3560-48PS/WS-C3750-48PS530W/540W—9166725201954169122181 WS-C3560G-48PS/WS-3750G-48PS590W—8146022182849148220165 WS-CE500-24PC460W—1120823024111662010927215

A Tripp Lite SNMP/Web card (model: SNMPWEBCARD) is recommended with each UPS system for remote power management. A Tripp Lite 2-post rackmount kit (model: 2POSTRMKITWM) is also recommended for systems that are going to be installed in 2-post rackmount environments.

Tripp Lite's PowerAlert Software, version 12.5, has tested compatible with Cisco CallManager, versions 4.0 and 4.1, Cisco 7600 Series Routers, 7500 Series Routers and Catalyst 65XX Layer 3 Switch. Tripp Lite PowerAlert Software, version 12, has tested compatible with Cisco CallManager, versions 3.3(4)-MCS and 4.0(2)-MCS. Go to www.tripplite.com/logodisclaimer for details. Tripp Lite is a Cisco Technology Developer Partner in the Cisco Technology Developer Program. Cisco, Cisco Systems, the Cisco Systems logo, and the Cisco Square Bridge logo are registered trademarks or trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries. SmartPro and SmartOnline are registered trademarks or trademarks of Tripp Lite.

200809088

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Tripp Lite SMX1500RXLRT2U+について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Tripp Lite SMX1500RXLRT2U+に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Tripp Lite SMX1500RXLRT2U+ 取扱説明書(PDF)

2 ページ·425 KB·電源ユニット·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…