Extron electronicメーカーMTP SW6の使用説明書/サービス説明書
ページ先へ移動 of 31
Ex tron US A - We st Headquar te rs +8 0 0.6 33 .9 876 I nside U SA / C anada Onl y +1 .7 14 .4 91 .1 50 0 +1 .7 14 .4 91 .1 51 7 FA X Ex tron US A - East +8 00 .6 33 .9 876 I nside U SA / C anada Onl y +1 .9 19 .8 63 .1 79 4 +1 .9 19 .8 63 .1 79 7 FA X Ex tron EM EA +8 00 .
Pr ecautions This symbol is intended to alert the user of important opera ting a nd ma inten ance ( serv icing ) inst ruct ions i n the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.
安全须知 • 中文 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 这个符号警告用户该设备机壳内有暴 露的危险电压,有触电危险。 .
i MTP SW6 • T able of Contents i T able of Contents Chapter One • Introduction .................................................... 1-1 About the MTP SW6 Switche ............................................... 1-2 RS-232 function ..............
ii MTP SW6 • T able of Contents T able of Contents, cont’d MTP SW6 1 Chapter One Intr oduction About the MTP SW6 Switcher T wisted Pair (TP) Cable Advantages 68-1462-01 Rev . A 11 08 All trademarks mentioned in this manual are the properties of their respective owners.
MTP SW6 • Intoduction Intr oduction MTP SW6 • Intoduction 1-2 1-3 The MTP switcher has image enhancement featur es that allow you to correct for long distance transmissions and skew: • Level and Peaking controls enhance the TP signals received on the inputs.
MTP SW6 • Intoduction Introduction, cont’d 1-4 MTP SW6 • Intoduction 1-5 T wisted Pair (TP) Cable Advantages T wisted pair cable is much smaller , lighter , more exible, and less expensive than coaxial cable. These TP pr oducts make cable runs simpler and less cumbersome.
MTP SW6 • Introduction 1-5 Recommended transmission distances at 60 Hz Video format MTP SW6 Pre-Peak High quality V ariable quality Off On Input a Output b Input a Output b Component, S-video, compo.
MTP SW6 • Intoduction Introduction, cont’d 1-6 MTP SW6 2 Chapter T wo Installation and Operation Mounting the Switcher Connectors and Settings Operation Optimizing the Video.
MTP SW6 • Installation and Operation Installation and Operation MTP SW6 • Installation and Operation 2-2 2-3 Mounting the Switcher The MTP SW6 can be set on a table, mounted on a rack shelf, or mounted under a desk, podium, or tabletop. T abletop use Four self-adhesive rubber feet are included with the switcher .
MTP SW6 • Installation and Opeation Installation and Operation, cont’d 2-4 MTP SW6 • Installation and Opeation 2-5 1U Universal Rac k Shelf Figure 2-2 — Mounting the MTP SW6 on a 1U, 9.5" deep universal rack shelf Furniture mounting For furniture mounting, do not attach the rubber feet.
MTP SW6 • Installation and Opeation Installation and Operation, cont’d 2-6 MTP SW6 • Installation and Opeation 2-7 Connectors and Settings REMOTE 123456 INPUT PRE-PEAK ON OFF OUTPUT MONO AUDIO OUTPUT LR POWER 12V 0.
MTP SW6 • Installation and Opeation Installation and Operation, cont’d 2-8 MTP SW6 • Installation and Opeation 2-9 f Mono Audio (local audio) output — Connect an audio device, such as an audio amplier or powered speakers to this 3.5 mm, 5-pole captive screw connector .
MTP SW6 • Installation and Opeation Installation and Operation, cont’d 2-10 MTP SW6 • Installation and Opeation 2-11 C Power supply voltage polarity is critical. Incorr ect voltage polarity can damage the power supply and the unit. The ridges on the side of the cord (figure 2-8) identify the power cord negative lead.
MTP SW6 • Installation and Opeation Installation and Operation, cont’d 2-12 MTP SW6 • Installation and Opeation 2-13 Receiver considerations N The receivers' buffer ed outputs do not provide pre-peaking contr ol. The total recommended distance for an entire daisy chain is the same as for a single transmitter and receiver .
MTP SW6 • Installation and Opeation Installation and Operation, cont’d 2-14 MTP SW6 • Installation and Opeation 2-15 h Delay Adjust (skew adjustment) control — This control delays the selected red, gr een, or blue video signal by up to 62 nanoseconds.
MTP SW6 • Installation and Opeation Installation and Operation, cont’d 2-16 MTP SW6 • Installation and Opeation 2-17 Optimizing the Video Most MTP transmitters and the MTP SW6 output have a pre- peaking feature. Set these features as follows for the best image quality: 1 .
MTP SW6 • Installation and Opeation Installation and Operation, cont’d 2-18 MTP SW6 3 Chapter Thr ee Remote Contr ol Simple Instruction Set Control Windows ® -Based Program Control Contact Closure Control IR 102 Infrared Remote Control 4 .
MTP SW6 • Remote Contol Remote Contr ol MTP SW6 • Remote Contol 3-3 3-2 The switcher can be remotely contr olled via its rear panel Remote connector (Figure 3-1).
MTP SW6 • Remote Contol Remote Control, cont’d 3-4 MTP SW6 • Remote Contol 3-5 Unit-initiated messages When a local event, such as a front panel operation, auto switch, or error condition, occurs, the unit r esponds by sending a message to the host.
MTP SW6 • Remote Contol Remote Control, cont’d 3-6 MTP SW6 • Remote Contol 3-7 Command ASCII Command (host to unit) Response (unit to host) Additional description Input selection N The switcher supports 1-, 2-, and 3-digit numeric entries (1!, 02&, or 003%).
MTP SW6 • Remote Contol Remote Control, cont’d 3-8 MTP SW6 • Remote Contol 3-9 Command/response table for SIS commands (continued) Command ASCII Command (host to unit) Response (unit to ho.
MTP SW6 • Remote Contol Remote Control, cont’d 3-10 MTP SW6 • Remote Contol 3-11 Command ASCII Command (host to unit) Response (unit to host) Additional description Audio input gain and attenuation N The set gain ( G ) and set attenuation ( g ) commands are case sensitive.
MTP SW6 • Remote Contol Remote Control, cont’d 3-12 MTP SW6 • Remote Contol 3-13 Command ASCII Command (host to unit) Response (unit to host) Additional description Switch mode Set normal (manual) switch mode 1# F1 ] The user selects inputs manually , from the front panel or under remote contr ol.
MTP SW6 • Remote Control Remote Control, cont’d 3-14 Command ASCII Command (host to unit) Response (unit to host) Additional description Information requests Information request I V X! •A X! •.
MTP SW6 • Remote Contol Remote Control, cont’d 3-14 MTP SW6 • Remote Contol 3-15 Command ASCII Command (host to unit) Response (unit to host) Additional description Information requests In.
MTP SW6 • Remote Contol Remote Control, cont’d 3-16 MTP SW6 • Remote Contol 3-17 4 . Follow the on-screen instr uctions. By default, the installation of the Universal Switchers Control Pr .
MTP SW6 • Remote Contol Remote Control, cont’d 3-18 MTP SW6 Contact Closure Remote Contr ol The Remote connector also provides a way to select an input to the switcher using a remote contact closur e device. Contact closure contr ol uses pins on the Remote connector that are not used by the RS-232 interface.
MTP SW6 • Refeence Infomation Refer ence Information MTP SW6 • Refeence Infomation A-2 A-3 Specifications Video Gain ................................................. Unity Video input — see MTP Series transmitter specifications Number/signal type .
MTP SW6 • Refeence Infomation Reference Information, c on t’ d MTP SW6 • Refeence Infomation A-4 A-5 Mounting Rack mount ........................ Y es, with optional 1U, 9.5" deep rack shelf (RSU 129, #60-190-01 or RSB 129, 60-604-01) or 1U, 6" deep rack shelf (RSU 126, #60-190-10 or RSB 126, 60-604-10) Furniture mount .
MTP SW6 • Refeence Infomation Reference Information, c on t’ d A-6 Cables N Enhanced Skew-Free™ A/V UTP cables ar e not recommended for Ethernet/LAN applications.
デバイスExtron electronic MTP SW6の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Extron electronic MTP SW6をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはExtron electronic MTP SW6の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Extron electronic MTP SW6の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Extron electronic MTP SW6で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Extron electronic MTP SW6を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はExtron electronic MTP SW6の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Extron electronic MTP SW6に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちExtron electronic MTP SW6デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。