HOME APPLIANCES Use 81 Care Information 30” and 36” Retractable Downdraft Vent Systems IMPORTANT: Read and save these instructions. IMPORTANT: Installer: Leave Installation Instructions with the homeowner. Homeowner: Keep Installation Instructions for future reference.
LUUII I~I UII I I~I Isions See cooktop Cutout width: manufacturer’s 30” vent - 2J- 112” instructions for ,,4” -:- -..1-... m,n, curour 36” vent - 33-112” cooktop cutout depth and width. --.. A = cabinet wall to rear line of cutout countertop Allow l/2” from rear of downdraft vent to back wall of cabinet.
Electrical requirements Before you start... Injury Hazard To eliminate the risk of burns or fire, avoid installing cabinet storage above the cooking surface. If cabinets are already installed, avoid the use of cabinets while cooktop is in use. Reaching over a heated cooking surface could result in a serious burn.
Venting requirements Built-in cabinet location Recommended standard fittings 3-,,4” x ,o” =II 3.114 x 10” to 6” 6” to 3-114” x IO” to 6” = 4.5 ft. 90” elbow = 5 ft. 90” elbow = 9 ft. :.-;-. . . . . . . . . . . . . . -. ..:.:.:.:.:.
If blower box is removed from vent base, check that wiring cable is properly secured in plastic clips. Interior-mounted blower Numbers correspond to steps. Determine which direction (down or rear) ductwork will need to run from blower duct when installed in cabinet.
Exterior-mounted vent motor 9” round ductwork system Injury Hazard Use two or more people to move and install downdraft vent. Failure to follow this instruction can result in back or other injury. NOTE: Exterior-mounted vent motor installations require exterior blower system, Part No.
Exterior-mounted blower into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is vertical.
Use & Care Information The retractable downdraft vent system is designed to remove smoke, cooking vapors and odors from the cook-top area. For the best results, the vent should be operating before cooking is started. If you use large or tall utensils, place them on the large rear element or burner surface.
If retractable downdraft vent does not operate... l Check that filters are pressed in as far as they will go. l Check that top corners of filter frame are pressed against microswitches located behind filter. l Check that the circuit breaker is not tripped or the house fuse blown.
デバイスKitchenAid 30" and 36" Retractable Downdraft Vent Systemsの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
KitchenAid 30" and 36" Retractable Downdraft Vent Systemsをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKitchenAid 30" and 36" Retractable Downdraft Vent Systemsの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。KitchenAid 30" and 36" Retractable Downdraft Vent Systemsの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。KitchenAid 30" and 36" Retractable Downdraft Vent Systemsで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
KitchenAid 30" and 36" Retractable Downdraft Vent Systemsを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKitchenAid 30" and 36" Retractable Downdraft Vent Systemsの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、KitchenAid 30" and 36" Retractable Downdraft Vent Systemsに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKitchenAid 30" and 36" Retractable Downdraft Vent Systemsデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。