36" Electric Fireplace P/N 775,172M REV . G 04/2007 MODEL: SA VE THESE INSTRUCTIONS FOR FUTURE REFERENCE MERIT ™ PLUS SERIES This manual will enable you to obtain a safe, efficient and dependable installation and operation of your electric fireplace.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 2 IM PO R T AN T SA FE TY A ND W A RN II NG I NF OR MA TI ON REA D T HIS MANU AL I N I TS ENT IRE TY A ND U NDER ST AND THE SE RULE S TO FOL LOW FOR SAF ETY . TO PREVENT A POSSIBLE FIRE, DO NOT BLOCK AIR INT AKES OR EXHAUSTS IN ANY WA Y .
W ARNING Do not i n st al l or o pe ra te t hi s fir e- p la c e t h ro u gh a sw i tc h wi r ed i n t h e 12 0 V AC or 24 0 V A C ci r cu it s. The on l y ap pr ov ed wi ri ng fo r a sw it c h is th ro ug h t he l o w vo lt ag e c ir cu it (2 4 V AC ) as s ho w n on P ag e 14 .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 4 FRAMING SPECIFICA TIONS 3 7- 5/ 8 " ( 95 4 m m) 2 4 " ( 61 0 m m) 1 4- 7/ 8 " ( 32 m m ) 5 -1 /8 " ( 13 0 m m) 3 6 " ( 91 4.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 5 Mantel Clearance: Combustibl e and Non-com- bustible mantels may be installed at any height above the top of the face of fireplace. Hearth Protection: A hearth is not mandatory , but it is recommended for aesthetic purposes.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 6 MANUAL CONTROL P ANEL OPERA TION (refer to Figures 5 & 6) Once this appliance has been properly installed and connected to the power supply as defined in this manual, it is ready to operate. Note: Ensure the circuit breakers for the power supply are turned on.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 7 • When using the remote control , the power on/off switch inside the body and the wall switch (optional kit) must be on the OFF position. REMOTE CONTROL OPERA TION: Figure 6 The Merit Plus Electric Fireplace is pro- vid ed wit h an Inf rared li gh t Remo te Con trol .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 8 Figure 9 MAINTENANCE This appliance has been designed to provide many years of trouble-free ser vice. The com- ponents that will need to be serviced have been kept to a minimum. Periodic dusting of the fireplace is all that should be required.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 9 Replacing Light Bulbs b. Flame Cylinder Bulbs i. Remove Brick panel, following proce- dur e on Pag e 8 (see Bric k pan el Remov al Procedure ). Figure 12 Ember Bed Figure 13 Bulb Bulb Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Brick panel Retain- ing brackets Flame Panel iii.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 10 WIRING DIAGRAM - 120 VOL T Wiring diagrams are provided here for reference purposes only . This information is also provided on schematics attached directly to the appliance on the left side. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 11 WIRING DIAGRAM - 240 VOL T Wiring diagrams are provided here for reference purposes only . This information is also provided on schematics attached directly to the appliance on the left side. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 12 5 V GROUND INSIDE POWER ON/OFF SWITCH (ON CONTROL PANEL) POWER ON/OFF SWITCH (OPTIONAL WALL SWITCH) OUTSIDE RED RED GREEN 1K POTENTIOMETER 5 V GROU.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 13 Installing Wall Thermostat (optional kit, see Page 18) Wire the wall thermostat prior to installing the fireplace. WALL THERMOST A T WIRING (24 VAC): Install Wall Thermostat per instructions provided with kit and per the following information: 1.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 14 Power On/Off Wall Switch Installation (optional kit, see Page 18) Wire the wall switch prior to installing the fireplace. WALL SWITCH WIRING (24 V AC): Install Wall Switch per instructions provided with kit and per the following information: 1.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 15 TROUBLESHOOTING Symptom Possible Causes Who Perf orm s Co rrec tive Action Corrective Action 1. Fireplace turns off and will not turn on and an audible beeping noise can be heard. Fireplace has overheated.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 16 REPLACEMENT P ARTS ITEM NO. DESCRIPTION MPE-36R CA T . NO. QTY 1 Bulb Kit, (10 Each 35w Halogen) H1623 1 2 Side Frames, 1 Left And 1 Right H1624 1 .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 17 REPLACEMENT P ARTS COMPONENT DIAGRAMS - MPE-36R 8b 23 14 16 11 1 4 2 5 6 6 7 8a 12 13 15 19 17 Front View POWER � ON/OFF � DISPLAY � ON/OFF � Dimmer � Brighter � EMBERS � HEATER � ON/OFF � TEMP.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 18 ACCESSORY COMPONENTS The following items are available for use with this appliance. Ca t. No . Mo de l De sc rip tio n H 1 53 5 GE P - 3 6B L Gl a .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 19 NOTES.
Printed in U.S.A. © LENNOX HEARTH PRODUCTS 2004 P/N 775,172M REV .G 04/2007 The manufacturer reser ves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
デバイスLennox Hearth MPE-36Rの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox Hearth MPE-36Rをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox Hearth MPE-36Rの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox Hearth MPE-36Rの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox Hearth MPE-36Rで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox Hearth MPE-36Rを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox Hearth MPE-36Rの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox Hearth MPE-36Rに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox Hearth MPE-36Rデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。