Part No. SP6549 Printed in Canada CAUTION READ ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLA TION. SA VE THIS OWNER’S MANUAL FOR FUTURE REFERENCE. Model No.
Safety Signal W ords DANGER: means if the safety information is not followed someone will be seriously injured or killed. WARNING: means if the safety information is not followed someone could be seriously injured or killed. CAUTION: means if the safety information is not followed someone may be injured.
Description MA 0950 Gallon Output/24 hrs 9.5 Capacity of Bottle 1.9 Gallons Capacity of Base 2.0 Gallons * Sq. Ft. Coverage 2000 Fan Speeds 3 Replacement Filter MAF-1 Power Light Y es Fill Light Y es Auto Humidistat Y es Auto Shut Off Y es Controls Rotary CUL Listed Y es V olts 120 A.
Carefully r emove the humidifier and all other contents from the carton. There is a black strip that contains six pads for the bottom of the humidifier . Remove each pad and place one on each of the six legs on the bottom of the base as shown, by the solid dots.
Location Instructions WARNING: For your own safety , do not use humidifier if any parts are damaged or missing. Step 1 Place humidifier on a flat level surface in an area of house wher e most humidity is needed, or one which would likely result in moist air being circulated thr oughout the house such as near a cold air return.
WARNING: T o reduce the risk of shock, always unplug humidifier before cleaning or servicing. WARNING: T o reduce the risk of fir e or shock hazard, do not pour or spill water into control or motor ar ea. If controls get wet, let them dry com- pletely and have unit checked by authorized service personnel before plugging in.
7 Position the water bottle back into the humidifier base to the right of the grille. The “Side Fill Cap” must be facing outward. When positioned pr operly , the plunger will open and water will flow into the base. The base will hold the entire contents of the water bottle.
Step 1 Be sure unit is full of water and plugged in. Step 2 Set the Speed Control to LOW ( ). Step 3 Set Humidity Control to a medium posi- tion (see diagram below) NOTE: Humidifier should operate with humidity control on the r ecommended medium setting.
WARNING: T o reduce the risk of shock or injury from moving parts, always unplug humidifier before removing or r eplacing any parts. CAUTION: T o help retard bacteria growth and keep maximum ef ficien- cy , the filter should be replaced at least once per season, or more often under hard water conditions.
5. Install a new filter (MAF-1) into the base. Coil the filter and position it between the uprights in the bottom of the base. The start and finish of the coil should be captured at the center of the base (see diagram) and the fil- ter should be resting on the floor of the base.
WARNING: T o reduce the risk of injury , fire or damage to humidifier , use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier . T o reduce the risk of scalds and damage to humidifier , never put hot water in humidifier .
Step 3 Bi-W eekly Maintenance Removing Scale 1. Fill the humidifier base with one 8 oz. cup of undiluted white vinegar . Let solution stay 20 minutes. 2. Clean all interior surfaces with a soft brush. Dampen a soft cloth with undiluted white vinegar and wipe out the base to remove scale.
T roubleshooting T rouble Power light not illuminated Unit will not run and Fill Light is not on. Note: Red power light is on. Unit will not cycle on and off. Unit will not shut off. Unit will not dry out completely . Bottle continues to empty . Unit is not emptying during use.
Repair Parts Parts List for MoistAir Humidifier Model No. MA 0950 0 14 SP6549 Manual 71235 7/12/05 3:17 PM Page 14.
Repair Parts Parts List for MoistAir Humidifier Model No. MA 0950 0 Always order by part number - Not by key number * Standard Har dware Item - May be purchased locally † Stock item - Purchase local.
© 2004 Emerson Part No. SP6549 Form No. SP6549 Printed in Canada 11/04 FOR TECHNICAL HELP , CALL (800) 654-3545 FROM USA OR (888) 744-4687 FROM CANADA (Please have complete model number) Emerson T ool Company For more information about MoistAir® humidifiers visit our website at www .
デバイスMoistAir MA 0950の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
MoistAir MA 0950をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMoistAir MA 0950の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。MoistAir MA 0950の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。MoistAir MA 0950で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
MoistAir MA 0950を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMoistAir MA 0950の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、MoistAir MA 0950に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMoistAir MA 0950デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。